Non-Newtonian flow calculation

2026-10-09 · CW-M-054 · Model version 1.01

Calculation content

Calculates flow rate, wall shear stress and apparent viscosity of a power-law fluid in fully developed laminar pipe flow.

Output quantities: Q (m³/s), τ_w (Pa), γ̇_w (1/s).

Inputs

InputSymbolUnitRequired
Consistency indexKPa·sⁿYes
Flow indexn1Yes
Pressure differencedpPaYes
Pipe radiusrmYes
Pipe lengthLmYes

Scope of application and preconditions

  • Power-law fluid, incompressible, fully developed laminar pipe flow, no slip at the wall.
  • K and n are treated as constant within one temperature and shear-rate range.
  • Inlet effects and viscous heating are neglected.
  • The Newtonian region at low shear rates or the second Newtonian plateau at high shear rates.
  • Turbulent or compressible flow.
  • Yield-stress fluids (Bingham/Herschel–Bulkley).

Use cases

Industries: fluid transport, polymer processing.

Products: pipe flow, extruded parts.

Model characteristics: power-law fluid, laminar flow, no slip.

Change history

  • 2026-10-09 · Version 1.01 · First release.