Non-Newtonian flow calculation
2026-10-09 · CW-M-054 · Model version 1.01
Calculation content
Calculates flow rate, wall shear stress and apparent viscosity of a power-law fluid in fully developed laminar pipe flow.
Output quantities: Q (m³/s), τ_w (Pa), γ̇_w (1/s).
Inputs
| Input | Symbol | Unit | Required |
|---|---|---|---|
| Consistency index | K | Pa·sⁿ | Yes |
| Flow index | n | 1 | Yes |
| Pressure difference | dp | Pa | Yes |
| Pipe radius | r | m | Yes |
| Pipe length | L | m | Yes |
Scope of application and preconditions
- Power-law fluid, incompressible, fully developed laminar pipe flow, no slip at the wall.
- K and n are treated as constant within one temperature and shear-rate range.
- Inlet effects and viscous heating are neglected.
- The Newtonian region at low shear rates or the second Newtonian plateau at high shear rates.
- Turbulent or compressible flow.
- Yield-stress fluids (Bingham/Herschel–Bulkley).
Use cases
Industries: fluid transport, polymer processing.
Products: pipe flow, extruded parts.
Model characteristics: power-law fluid, laminar flow, no slip.
Change history
- 2026-10-09 · Version 1.01 · First release.