Capillary rise height
2026-11-02 · CW-M-042 · Model version 1.01
Calculation content
Calculates capillary rise or depression height from surface tension, contact angle, density and capillary radius.
Output quantity: h (m), h (mm).
Inputs
| Input | Symbol | Unit | Required |
|---|---|---|---|
| Surface tension | gamma | N/m | Yes |
| Contact angle | theta | rad | Yes |
| Liquid density | rho | kg/m³ | Yes |
| Capillary radius | r | m | Yes |
| Gravitational acceleration | g | m/s² | No |
Scope of application and preconditions
- Round tube with a uniform inner wall; the liquid is incompressible.
- A fully developed static meniscus; dynamic contact angle and inertia are neglected.
- γ, ρ and θ are treated as constant across the temperature field.
- Tube diameter far larger than the capillary length (results are not physically meaningful).
- Contact angle hysteresis, dynamic wetting, evaporation, surfactants.
- Non-circular cross-sections, rough walls or porous media.
Use cases
Industries: porous materials, fibers and textiles.
Products: capillaries, porous media.
Model characteristics: round tube, static meniscus, uniform inner wall.
Change history
- 2026-11-02 · Version 1.01 · First release.