Lumped-capacitance cooling

2026-10-05 · CW-M-030 · model version 1.01

Calculation content

Uses the lumped-capacitance model to calculate how the mean body temperature changes with time.

Output quantities: τ (s), T (K).

Inputs

InputsSymbolUnitRequired
MassmkgYes
Specific heat capacitycpJ/(kg·K)Yes
Convective heat transfer coefficienthW/(m²·K)Yes
Heat transfer areaAm²Yes
Thermal conductivitykW/(m·K)Yes
Characteristic lengthL_cmYes
Initial temperatureT0KYes
Ambient temperatureT_infKYes
Cooling timetsYes

Scope of application and preconditions

  • Uniform temperature inside the body (Biot number Bi < 0.1).
  • h and cp are treated as constant during the process, and ambient temperature is constant.
  • No internal heat source, radiation, phase change or contact resistance.
  • Validation: k and the characteristic length L_c are required inputs, and Bi = h·L_c/k is checked. Bi ≥ 0.1 returns E_APPLICABILITY; a missing input returns E_MISSING_INPUT.
  • Bi ≥ 0.1, which needs a one- or multi-dimensional transient conduction solution.
  • Significant surface radiation, strongly varying natural convection, or phase change.

Use cases

Industries: thermal management, process cooling.

Products: small components, sensor packages.

Model characteristics: low Biot number, uniform internal temperature, convective boundary.

Change history

  • 2026-10-05 · version 1.01 · First release.