Lumped-capacitance cooling
2026-10-05 · CW-M-030 · model version 1.01
Calculation content
Uses the lumped-capacitance model to calculate how the mean body temperature changes with time.
Output quantities: τ (s), T (K).
Inputs
| Inputs | Symbol | Unit | Required |
|---|---|---|---|
| Mass | m | kg | Yes |
| Specific heat capacity | cp | J/(kg·K) | Yes |
| Convective heat transfer coefficient | h | W/(m²·K) | Yes |
| Heat transfer area | A | m² | Yes |
| Thermal conductivity | k | W/(m·K) | Yes |
| Characteristic length | L_c | m | Yes |
| Initial temperature | T0 | K | Yes |
| Ambient temperature | T_inf | K | Yes |
| Cooling time | t | s | Yes |
Scope of application and preconditions
- Uniform temperature inside the body (Biot number Bi < 0.1).
- h and cp are treated as constant during the process, and ambient temperature is constant.
- No internal heat source, radiation, phase change or contact resistance.
- Validation: k and the characteristic length L_c are required inputs, and Bi = h·L_c/k is checked. Bi ≥ 0.1 returns E_APPLICABILITY; a missing input returns E_MISSING_INPUT.
- Bi ≥ 0.1, which needs a one- or multi-dimensional transient conduction solution.
- Significant surface radiation, strongly varying natural convection, or phase change.
Use cases
Industries: thermal management, process cooling.
Products: small components, sensor packages.
Model characteristics: low Biot number, uniform internal temperature, convective boundary.
Change history
- 2026-10-05 · version 1.01 · First release.