Specific heat back-calculation from temperature rise
2026-10-01 · CW-M-029 · model version 1.01
Calculation content
Back-calculates the mean specific heat capacity at constant pressure from heat, mass and temperature difference.
Output quantity: cp (J/(kg·K)), cp (kJ/(kg·K)).
Inputs
| Inputs | Symbol | Unit | Required |
|---|---|---|---|
| Sensible heat | Q | J | Yes |
| Mass | m | kg | Yes |
| Temperature change | dT | K | Yes |
Scope of application and preconditions
- All heat goes into sensible heat of that mass, without losses, reaction heat or latent heat.
- Specific heat capacity is treated as constant over the temperature range.
- Heat uptake and temperature rise are positive, heat release and cooling negative, with consistent signs.
- Check: |ΔT| < 1e-6 K is not treated as an error; the result is still returned but marked degraded=true with the notice “highly sensitive to measurement error”. A cp outside [1, 1e6] J/(kg·K) yields E_OUT_OF_RANGE.
- Phase change, reaction, significant heat loss or work transfer.
- Temperature differences near 0, where the result is highly sensitive to measurement error.
Use cases
Industries: materials testing, thermal management.
Products: test specimens, thermal management parts.
Model characteristics: all heat becomes sensible heat, no phase change, no heat loss.
Change history
- 2026-10-01 · version 1.01 · First release.