Sensible heat calculation
2026-10-01 · CW-M-028 · model version 1.01
Calculation content
Calculates sensible heat from mass, specific heat capacity at constant pressure and temperature difference.
Output quantity: Q (J), Q (kJ).
Inputs
| Inputs | Symbol | Unit | Required |
|---|---|---|---|
| Mass | m | kg | Yes |
| Specific heat capacity at constant pressure | cp | J/(kg·K) | Yes |
| Temperature change | dT | K | Yes |
Scope of application and preconditions
- Specific heat capacity is treated as constant over the temperature range.
- The system is closed, with no mass flow, chemical reaction or phase change.
- The temperature change is uniform over the whole body, without temperature gradients.
- Phase change, decomposition or glass transition, which need latent heat added or an enthalpy difference instead.
- cp varies strongly with temperature, so an integrated mean heat capacity is needed.
- Open systems where heat loss, reaction heat or mechanical work must be included.
Use cases
Industries: thermal management, process heating.
Products: heating elements, insulated structures.
Model characteristics: no phase change, constant pressure, no heat loss.
Change history
- 2026-10-01 · version 1.01 · First release.