Capillary flow calculation
2026-10-09 · CW-M-023 · model version 1.01
Calculation content
Calculates laminar flow rate and velocity of a Newtonian fluid in a capillary.
Output quantities: Q (m³/s), v (m/s), Re, L_e (m).
Inputs
| Inputs | Symbol | Unit | Required |
|---|---|---|---|
| Dynamic viscosity | μ | Pa·s | Yes |
| Pressure difference | Δp | Pa | Yes |
| Capillary radius | r | m | Yes |
| Capillary length | L | m | Yes |
| Fluid density | ρ | kg/m³ | No |
| Viscosity source | source_mu | — | No |
| Density source | source_rho | — | No |
Scope of application and preconditions
- Newtonian fluid: viscosity is independent of shear rate and constant along the whole tube.
- Laminar flow (Re < 2300), fully developed, axisymmetric, incompressible.
- Straight circular tube of constant cross-section, no slip at the wall, rigid and smooth wall.
- Steady flow, without local losses or additional gravitational or capillary pressure difference, or such effects already included in Δp.
- Non-Newtonian fluids with shear thinning or thickening, yield stress or viscoelasticity; use power-law or Bingham models instead.
- Transitional and turbulent flow (Re ≥ 2300); use the Moody chart or Darcy–Weisbach instead.
Use cases
Industries: rheology and dispensing, chemical process engineering.
Products: capillaries, dispensing needles.
Model characteristics: Hagen–Poiseuille, Newtonian fluid, laminar flow.
Change history
- 2026-10-09 · version 1.01 · First release.