Capillary flow calculation

2026-10-09 · CW-M-023 · model version 1.01

Calculation content

Calculates laminar flow rate and velocity of a Newtonian fluid in a capillary.

Output quantities: Q (m³/s), v (m/s), Re, L_e (m).

Inputs

InputsSymbolUnitRequired
Dynamic viscosityμPa·sYes
Pressure differenceΔpPaYes
Capillary radiusrmYes
Capillary lengthLmYes
Fluid densityρkg/m³No
Viscosity sourcesource_mu—No
Density sourcesource_rho—No

Scope of application and preconditions

  • Newtonian fluid: viscosity is independent of shear rate and constant along the whole tube.
  • Laminar flow (Re < 2300), fully developed, axisymmetric, incompressible.
  • Straight circular tube of constant cross-section, no slip at the wall, rigid and smooth wall.
  • Steady flow, without local losses or additional gravitational or capillary pressure difference, or such effects already included in Δp.
  • Non-Newtonian fluids with shear thinning or thickening, yield stress or viscoelasticity; use power-law or Bingham models instead.
  • Transitional and turbulent flow (Re ≥ 2300); use the Moody chart or Darcy–Weisbach instead.

Use cases

Industries: rheology and dispensing, chemical process engineering.

Products: capillaries, dispensing needles.

Model characteristics: Hagen–Poiseuille, Newtonian fluid, laminar flow.

Change history

  • 2026-10-09 · version 1.01 · First release.