Conduction thickness back-calculation
2026-09-18 · CW-M-022 · model version 1.01
Calculation content
Back-calculates the conduction layer thickness from heat flow, temperature difference and thermal conductivity.
Output quantities: L (m), R_th, Q.
Inputs
| Inputs | Symbol | Unit | Required |
|---|---|---|---|
| Thermal conductivity | k | W/(m·K) | Yes |
| Heat transfer area | A | m² | Yes |
| Temperature difference | ΔT | K | Yes |
| Heat flow rate | Q | W | Yes |
| Thermal conductivity source | source_k | — | No |
Scope of application and preconditions
- One-dimensional steady-state conduction: heat flows only through the thickness. Area and temperature difference are uniform across the thickness, with no lateral heat flow.
- The material is homogeneous and isotropic, with constant thermal conductivity across the thickness, or an integrated mean value.
- No heat accumulates under steady-state conditions, and both surface temperatures are known and constant.
- Contact resistance, convection, radiation and edge losses are not included.
- Transient conduction, cyclic thermal loading and thermal shock.
- Multilayer walls, which need layer-by-layer thermal resistance in series. This model gives only a single-layer equivalent thickness.
Use cases
Industries: thermal management, electronics cooling.
Products: insulation layers, thermal pads.
Model characteristics: one-dimensional steady state, no contact resistance.
Change history
- 2026-09-18 · version 1.01 · First release.