Conduction thickness back-calculation

2026-09-18 · CW-M-022 · model version 1.01

Calculation content

Back-calculates the conduction layer thickness from heat flow, temperature difference and thermal conductivity.

Output quantities: L (m), R_th, Q.

Inputs

InputsSymbolUnitRequired
Thermal conductivitykW/(m·K)Yes
Heat transfer areaAm²Yes
Temperature differenceΔTKYes
Heat flow rateQWYes
Thermal conductivity sourcesource_k—No

Scope of application and preconditions

  • One-dimensional steady-state conduction: heat flows only through the thickness. Area and temperature difference are uniform across the thickness, with no lateral heat flow.
  • The material is homogeneous and isotropic, with constant thermal conductivity across the thickness, or an integrated mean value.
  • No heat accumulates under steady-state conditions, and both surface temperatures are known and constant.
  • Contact resistance, convection, radiation and edge losses are not included.
  • Transient conduction, cyclic thermal loading and thermal shock.
  • Multilayer walls, which need layer-by-layer thermal resistance in series. This model gives only a single-layer equivalent thickness.

Use cases

Industries: thermal management, electronics cooling.

Products: insulation layers, thermal pads.

Model characteristics: one-dimensional steady state, no contact resistance.

Change history

  • 2026-09-18 · version 1.01 · First release.