From a literature elastic modulus to one beam bending frequency calculation
2026-11-12 · A straight glass-fibre epoxy beam with 0/90° layup. The modulus comes from literature, the density is assumed for the case. The first bending frequency is computed and checked by hand.
Task and final result of this entry
A rectangular straight beam of glass-fibre epoxy laminate with 0/90° layup is taken. Its first bending natural frequency is estimated to give a first check of resonance risk.
Case: elastic modulus 60.5 GPa, density 1600 kg/m³ (assumed), cross-section 20 mm × 10 mm. Span 1.0 m, simply supported at both ends. The result is a frequency value with source of the reference value, the formula and a hand check.
Why this was done
It was chosen because it has few inputs and clear assumptions. Five items - modulus, density, cross-section, length and boundary conditions - give the frequency. Every step can be recomputed independently by a third party.
This entry does not cover mode shapes, damping ratios or frequency response functions. It also does not judge whether the beam design is acceptable.
Previous practice and current practice
Previously the modulus was looked up in a literature table and copied into a calculator. It was inserted into f = (λ²/2πL²)·sqrt(EI/ρA), and the numbers were transcribed into a document. Looking back later, it was hard to state which record and which version were used.
Now value selection, substitution and verification form one repeatable path. The modulus is taken from a literature record. Geometry and density are set by the case. Both input classes are labelled with their source. The result carries its formula and validity limits.
Workflow record of this entry
- One record with 0/90° layup and modulus 60.5 GPa was identified, referring to 10.1016/j.compstruct.2018.03.065.
- The cross-section is entered as a rectangle, width 20 mm and height 10 mm. This gives A = 2.0×10⁻⁴ m² and I = 1.6667×10⁻⁹ m⁴.
- Density is assumed as 1600 kg/m³ for the case, giving ρA = 0.320 kg/m.
- Boundary conditions are simply supported at both ends, first mode n = 1, frequency parameter λ₁ = π.
- Substitution gives the angular frequency ω₁ = 175.197 rad/s and the natural frequency f₁ = 27.8835 Hz.
Evidence of the outcome
No time comparison with a purely manual process was recorded, so no improvement ratio is given.
Only one thing can be confirmed: with the same inputs, anyone recomputing with the parameters below obtains the same results.
Observations and uncertainties
- Density is an assumed value. Moving it by 100 kg/m³ up and down changes the frequency by about +3.3% / −3.0%. That sensitivity is lower than for the modulus.
- 60.5 GPa is the equivalent modulus of the 0/90° laminate. The beam model treats the material as isotropic, so the result only indicates a trend.
- Simply supported is an ideal boundary. Real supports have compliance, so measured frequencies are usually lower than calculated values.
- The slenderness ratio L/r ≈ 346 is far above 10, so shear deformation and rotary inertia can be neglected.
Independent check and validity limits
A = 0.020 × 0.010 = 2.0000e-4 m2
I = 0.020 × 0.010^3 / 12 = 1.6667e-9 m4
EI = 6.05e10 × 1.6667e-9 = 100.833 N·m2
rhoA = 1600 × 2.0000e-4 = 0.320 kg/m
sqrt(EI/rhoA) = sqrt(315.10) = 17.7512 m2/s
omega1 = pi^2 × 17.7512 = 175.197 rad/s
f1 = 175.197 / (2*pi) = 27.8835 Hz
L/r = 1.0 / 2.8868e-3 = 346
Scope of application: straight beams of constant cross-section, homogeneous and isotropic. Slenderness is at least 10 and vibration is small-amplitude linear elasticity. Not applicable to short thick beams, tapered beams or sandwich beams. Also not applicable where mode shapes or damping are required.
One-click reproduction
Submit the parameters below as they are to obtain the same results.
{
"module": "CW-M-019",
"E": {"value": 60.5, "unit": "GPa"},
"rho": {"value": 1600, "unit": "kg/m3"},
"section": {"type": "rect",
"width": {"value": 0.02, "unit": "m"},
"height": {"value": 0.01, "unit": "m"}},
"L": {"value": 1.0, "unit": "m"},
"bc": "simply_supported",
"n": 1
}
Discussion question
When slenderness lies between 10 and 20, is a shear-corrected beam model preferable, or a modal test on the component? Judgements with reasons are welcome.
References
10.1016/j.compstruct.2018.03.065
